Cable Sizing and Rating

Electric Systems, Mark1 Conversions, Tips

Cable Sizing and Rating

Knowing the correct cable size is crucial to the safety of your van. AWGClosest mm2Amp18 AWG1 mm16 amp15 AWG1.5 mm21 amp14 AWG2 mm25 amp12 AWG3 mm33 amp10 AWG6 mm50 amp7 AWG10 mm70 amp6 AWG16 mm110 amp4 AWG20 mm135 amp3 AWG25 mm170 amp2 AWG35 mm240 amp0 (1/0) AWG50 mm345 amp00 (2/0) AWG70 mm485 amp When selecting […]

Article Tags: AMPs, AWG, Cable Sizes

Knowing the correct cable size is crucial to the safety of your van.

AWGClosest mm2Amp
18 AWG1 mm16 amp
15 AWG1.5 mm21 amp
14 AWG2 mm25 amp
12 AWG3 mm33 amp
10 AWG6 mm50 amp
7 AWG10 mm70 amp
6 AWG16 mm110 amp
4 AWG20 mm135 amp
3 AWG25 mm170 amp
2 AWG35 mm240 amp
0 (1/0) AWG50 mm345 amp
00 (2/0) AWG70 mm485 amp

When selecting your cable you need to make sure that:

  • It has a sufficient current rating for the expected load in the circuit, including a margin of safety.
  • The intended cable run length will not cause a voltage drop of more than about 3%
  • The material properties are appropriate for the application

Get these right and you can be confident that your cable is right for the job!

MARK1 CONVERSIONS

Start your journey today

Find our what's possible with your van

Ready to Start Your Adventure?

Whether you’re dreaming of a full camper conversion or just the first steps of your build, we’ll guide you from design to delivery. Honest advice, transparent pricing, and craftsmanship you can trust.

REQUEST A QUOTE

Request a quote today

Send us your details and a member of our team will come back to you as soon as possible.

BOOK YOUR CONSULTATION

We are officially Mark1 Conversions Ltd, a UK-registered Limited Company (See here for our registered address)

Our registered number is 5517554.

Website Design & Marketing by Vector7